PROTEIN AND NIR ANALYSIS

Protein Determination Devices

Plan the sample, parameter and analysis speed together.

Determine the sample type, calibration and reporting basis together for protein determination in grain and flour. Compare systems like XGrain/SGrain and NIR/NIT based on your application.

3 catalog product Türkiye overall support Setup and technical service
CATEGORY PRODUCTS

Protein Determination Device models

3 product listing
İnfracont Infracont SGrain Portable NIR Analyser
NIR analysers, Protein Determination Devices, Grain analysers

Infracont SGrain Portable NIR Analyser

Infracont SGrain is the NIR analyser we manufacture to bring protein, moisture and calibration-dependent composition analysis of grain and flour samples to different work locations. It can operate with an external 12 V power supply.

İnfracont Infracont XGrain NIR Grain Analyser
NIR analysers, Protein Determination Devices, Grain analysers

Infracont XGrain NIR Grain Analyser

Infracont XGrain is the NIR grain analyser we manufacture for grain intake points and laboratories. It combines built-in hectolitre weight measurement with protein, moisture and other composition results supported by the application.

ANALYSER SELECTION GUIDE

Position the protein analysis system correctly

Not only protein measurement but also sample structure, calibration scope and daily workflow are decisive in device selection.

01

sample structure

Determine the appropriate optical method and sample container for whole grain, milled sample, flour or oilseed.

02

Parameter scope

Clarify the need for moisture, fat, gluten, starch or hectoliter along with protein, depending on the application.

03

Calibration and data

Verify product calibrations, reference method, reporting and connectivity needs prior to purchase.

AREAS OF USE

What workflows does this category serve?

Protein determination systems support rapid decision-making from grain acceptance to production control. Optical methods and sample preparation requirements used in whole grain, milled sample and flour applications may differ.

Device selection; The products to be measured, required parameters, analysis capacity, existing reference methods and calibration management should be considered together.

  • Grain acceptance laboratories
  • Flour and feed factories
  • oilseed processing
  • Licensed warehouses
  • Seed quality control
  • Production process control

On what basis will the protein result be compared?

Rapid protein analysis supports decision making in grain acceptance and production control with appropriate calibration. When comparing the device result with the reference laboratory, the sample must represent the same batch and the moisture basis and nitrogen-protein conversion factor must be compatible.

Scroll horizontally to see the rest of the table.

Pre-purchase control framework
decision titleInformation to be verified in the offer
sample typeIndividual calibration match for wheat, marjoram, barley, flour or other product.
Result basisRecord of dry matter/original sample and protein factor used.
Reference comparisonAppropriate reference method, same sample and acceptance criteria.
Additional parametersFurther verification of moisture, gluten, fat or other results in the relevant product.

Calibration, device and scope of offer

Review protein coverage on XGrain and SGrain with the sample matrix on the product pages; Include the cuvette for flour in the selection. The reference method is used to develop and monitor the performance of the NIR calibration. The same accuracy or suite of parameters should not be assumed for all samples until the desired products and ranges are clear.

Check out calibration and reference verification support or Request a quote for the device suitable for your sample.

MODEL COMPARISON

XGrain or SGrain?

Consider two NIR analysers based on your hectoliter measurement, display and portable usage needs.

XGrain and SGrain: the choice according to the way you work
FeatureInfracont XGrain Infracont SGrain
Featured usageGrain intake and laboratoryPortable analysis at different points
Hectolitre weightBuilt-in measurement moduleNo internal module in standard model
Screen8 inch touch5,7 inch touch
Weight13 kg10 kg
Analysis timeApproximately 1 minutesApproximately 1 minutes
internal printerThermalThermal

Standard model catalog values ​​are taken as basis. Sample type, installed calibrations, accessories and configuration to be delivered are verified together at the time of quotation.

TECHNICAL SERVICE AND APPLICATION SUPPORT

Let's verify the calibration scope together.

Share the products and parameters you want to measure; Let's determine the appropriate device, calibration and installation scope.

Get Technical Support
FREQUENTLY ASKED QUESTIONS

before you decide

Why is the dry matter basis important as a result of protein?

Results reported for different moisture bases may not be directly comparable. The reference method and the conversion factor should be checked together with the basis in the device report.

Does NIR completely replace the reference assay in protein determination?

NIR provides fast routine control; Reliable reference results are required to establish and monitor calibration. The intended use and quality procedure are determined together.

Are protein and ash in the same scope for flour?

It is verified which parameters are included in the relevant flour calibration. The flour cuvette and calibration package are evaluated together; This scope does not generalize to all grains.

RELATED GUIDES

technical information center

SELECTION AND APPLICATION

Related guides and support

Evaluate your model choice together with the area of ​​use, sample and scope of delivery.