XGrain or SGrain? First determine the measuring point
XGrain at fixed reception point and laboratory where it is necessary to measure hectolitre on the same device;SGrain is evaluated in the analysis order to be carried to different operating points. The standard SGrain does not have an internal hectoliter module. The combination outputs of the two devices depend on the product and parameter calibration.
Portability doesn't mean uninterrupted outdoor use or built-in battery. For the SGrain, suitable external power supply and environmental conditions suitable for the model must be planned. If hectoliters are mandatory, include the need for separate equipment in the total quotation.
Technical differences and common points
| Title | XGrain | SGrain |
|---|---|---|
| Usage focus | Fixed intake / laboratory | Analysis that can be carried to different points |
| Hectolitre weight | Built-in measurement module | No internal module in standard model |
| Weight | 13 kg | 10 kg |
| Screen | 8 inch touch | 5,7 inch touch |
| Dimension (W×H×D) | 350 × 430 × 330 mm | 350 × 340 × 330 mm |
| Analysis | Approximately 1 minutes | Approximately 1 minutes |
| Printer | Internal thermal | Internal thermal |
| Strength | 100–240 VAC / 12 V, 10 A adapter | 100–240 VAC adapter;suitable 12 V external power supply option |
| operating temperature | 10–45 °C | 10–45 °C |
Table is based on standard model sheets. Preparation, cleanup, and recording are included in the total workflow time. The current delivery version, power accessories and operating environment are verified before ordering.
Decision in three use cases
| Need | Startup option | The question that completes the decision |
|---|---|---|
| Composition + hectolitre at vehicle acceptance | XGrain | Is the sampling, recording and cycling capacity appropriate? |
| Check at different pickup points | SGrain | Are transportation, external power and environmental conditions met? |
| Quick analysis in flour quality control | Both models, with appropriate coverage | Are the flour cuvette, calibration and reference method appropriate? |
These scenarios are not actual customer cases or performance experiments;is the selection frame.A model should not be selected based solely on display or weight until the products to be measured and the workflow are clear.
Do two models measure the same parameters in every sample?
No. Supported parameters of each product are checked separately. For example, protein, moisture, gluten and Zeleny for wheat in the factory list; For rapeseed, it contains oil and moisture. Wheat flour requires appropriate flour cuvette. Being on the same list does not mean that all calibrations are installed on the delivered device.
For calibration selection, the product, parameter, expected range, reporting basis and reference method should be shared. Verification guide And calibration service scope This is a continuation of the decision.
How do you compare two quotes on the same scope?
- Compare model and delivery configuration.
- Print product/parameter calibrations line by line.
- Separate flour tray, external power, transport and printer consumable.
- Ask about data transfer, software and cloud access conditions, if applicable.
- See installation, training and application verification in separate items.
- Clarify the current price, deadline, warranty and service scope in writing.
For current price, delivery schedule and service scope XGrain product page And SGrain product page Check it out. Request a model quote with your sample and working location.
Resources and technical basis
Frequently Asked Questions
Does the SGrain have internal hectolitre measurement?
The standard SGrain does not have an internal hectoliter module. This need must be evaluated with the internal module of the XGrain or with suitable separate equipment.
Since SGrain is portable, is it powered by internal battery?
Portable body means no built-in battery. Suitable external 12 V supply and power accessories must be verified together with the scope of delivery.
Are all calibrations included in the delivery for both models?
The factory list does not indicate that all applications are included in the delivery package. Product, parameters, calibration license and accessories must be specified separately in the offer.
Let's determine the appropriate configuration together.
Share your samples and where the device will be used. Let's clarify the model, calibration and offer conditions.