Infracont XGrain NIR Grain Analyser
Infracont XGrain provides protein, moisture and other composition results suitable for the application at the grain receiving point and in the laboratory with internal hectolitre measurement.

Infracont SGrain is the NIR analyser we manufacture to bring protein, moisture and calibration-dependent composition analysis of grain and flour samples to different work locations. It can operate with an external 12 V power supply.
If you want to analyze samples at different receiving or production points rather than transporting them to a single laboratory, consider the SGrain. The 10 kg housing, 5,7 inch touch screen and built-in thermal printer enable on-site measurement and recording flow under suitable operating conditions.
External power supply, cable and connection compatibility for 12 V use are determined at the offer stage. Plan work surface, environmental temperature, and sample preparation setup as well as frequency of handling. The standard SGrain does not have an internal hectoliter module;when this measurement is required on the same device Model XGrain Check it out. Compare the usage differences of the two models.
Check product–parameter match for whole grains, oilseeds and flour/milled samples with appropriate cuvette. The following examples were selected from the factory calibration list; The package installed on the device to be delivered is also verified.
Scroll horizontally to see the rest of the table.
| Sample | Listed parameters | Application condition |
|---|---|---|
| Wheat | Protein, moisture, gluten, Zeleny | Whole grain;corresponding wheat calibration |
| Durum wheat | Protein, moisture, gluten | Status calibration is selected separately |
| Barley | protein, moisture | Summer/winter product coverage is verified |
| Sweetcorn | Protein, moisture, starch, fat | Convenient corn calibration and measuring range |
| Soy | Protein, moisture, fat | Reporting basis is checked |
| Rape | oil, moisture | Protein coverage is not assumed |
| wheat flour | Protein, moisture, gluten, ash | Separate flour cuvette required |
| Semolina | protein, moisture | Proper cuvette and grit calibration required |
The list does not include all applications. Measurement range, reporting basis and compliance with reference results are evaluated separately for each product. Hectolitre measurement is specified in the factory listing only for XGrain.
Scroll horizontally to see the rest of the table.
| Feature | Standard model information |
|---|---|
| Analysis method | Near infrared transmission (NIR / NIT) |
| optical system | SBCS scanning grating monochromator |
| Spectral range | 790–1064 nm (product sheet) |
| Analysis time | Approximately 1 minutes |
| Hectolitre weight | No internal hectoliter module in standard model |
| Screen | 5,7 inch, 640 × 480 color touch |
| Dimensions (W×H×D) | 350 × 340 × 330 mm |
| Weight | 10 kg |
| Supply | 100–240 VAC / 12 V / 10 A |
| power consumption | 50 VA |
| operating temperature | 10–45 °C |
| Optical path length | 4–33 mm, automatic tuning |
| Printer | Built-in thermal printer |
| Links | 3 × USB 2.0, LAN, Wi-Fi |
The technical chart is based on the official model sheet. The version and hardware scope to be delivered are specified in the offer. Analysis time belongs to the measurement of a sample; Sample acceptance, cleaning and verification steps are also included in the daily capacity calculation.
In order for the device to convert the spectrum into a result, calibration of the relevant product and component is required. The information “measures wheat” does not mean that the same package covers every grain or all parameters. Specify the sample type, target parameter, expected upper/lower values, and reference analysis method.
The nitrogen–protein factor used in the protein result and the dry matter/original sample basis should be comparable. Determine acceptance criteria by comparing instrument and reference results with representative samples at the installation; Review the inspection plan after new crop, season or maintenance. Explore the scope of calibration and verification service.
Scroll horizontally to see the rest of the table.
| Pen | How to clarify? |
|---|---|
| Flour and ground sample cuvette | Required for these applications; The suitable cuvette and its quantity are stated in the delivery list. |
| Power supply and connections | Specify appropriate external power supply and handling/installation conditions for different operating points. |
| Calibration package | Products, parameters, measuring ranges and the package to be installed are listed. |
| Printer and consumables | Internal printer is a standard model feature; Delivery of paper and consumables is also stated. |
| InfraCloud and data transfer | Internet connection, access conditions and desired recording/transfer flow are evaluated together. |
| Installation, training and transportation | Application location, number of users, delivery and service scope are explained in separate items in the offer. |
Instead of pricing the model on its own, define the package that will work in your business. Include sample types, parameters, number of samples per day, study location and available reference method in your request for quotation. Device configuration, calibrations, cuvettes, power/connection accessories, training and delivery plan are prepared with these needs.
Current price, deadline, warranty and service conditions will be clarified in your written offer. Request a quote suitable for your sample for Infracont SGrain.
Appropriate calibration is required for each product–parameter pair. The measuring range of the loaded package and sample is verified at the time of quotation and installation.
A separate, suitable flour pan is required for flour and associated milled samples. Calibration and cuvette are selected together.
The range and statistics given in the list indicate the definition of the relevant calibration. The suitability of the delivered device on your real samples is evaluated by reference comparison.
Let our expert team determine the right analysis system according to your needs.
Review relevant models, selection guide and support coverage for your application.
Analytics and marketing cookies are used only with your consent. You can accept, reject or change your preferences.
Required for the website to function correctly and securely. These cannot be disabled.
Help us understand website use and improve performance.
May be used to measure campaigns and personalise advertising.