Infracont SGrain Portable NIR Analyser
new device NIR analysers İnfracont

Infracont SGrain Portable NIR Analyser

Infracont SGrain is the NIR analyser we manufacture to bring protein, moisture and calibration-dependent composition analysis of grain and flour samples to different work locations. It can operate with an external 12 V power supply.

  • Technical Information and Quotation
  • Application-Based Assessment
  • Service and Installation Information
  • Contact for Enquiries throughout Türkiye
  • Warranty and Instrument Condition Get product-specific warranty and technical status information in your offer.
  • Installation and Training Information Let's clarify the scope of installation and user training together.
  • Technical Service Request Discuss service options based on your device model and location.

For which workflow is the SGrain chosen?

If you want to analyze samples at different receiving or production points rather than transporting them to a single laboratory, consider the SGrain. The 10 kg housing, 5,7 inch touch screen and built-in thermal printer enable on-site measurement and recording flow under suitable operating conditions.

External power supply, cable and connection compatibility for 12 V use are determined at the offer stage. Plan work surface, environmental temperature, and sample preparation setup as well as frequency of handling. The standard SGrain does not have an internal hectoliter module;when this measurement is required on the same device Model XGrain Check it out. Compare the usage differences of the two models.

Sample types and measured parameters

Check product–parameter match for whole grains, oilseeds and flour/milled samples with appropriate cuvette. The following examples were selected from the factory calibration list; The package installed on the device to be delivered is also verified.

Scroll horizontally to see the rest of the table.

Example sample–parameter matches
SampleListed parametersApplication condition
WheatProtein, moisture, gluten, ZelenyWhole grain;corresponding wheat calibration
Durum wheatProtein, moisture, glutenStatus calibration is selected separately
Barleyprotein, moistureSummer/winter product coverage is verified
SweetcornProtein, moisture, starch, fatConvenient corn calibration and measuring range
SoyProtein, moisture, fatReporting basis is checked
Rapeoil, moistureProtein coverage is not assumed
wheat flourProtein, moisture, gluten, ashSeparate flour cuvette required
Semolinaprotein, moistureProper cuvette and grit calibration required

The list does not include all applications. Measurement range, reporting basis and compliance with reference results are evaluated separately for each product. Hectolitre measurement is specified in the factory listing only for XGrain.

Infracont SGrain specifications

Scroll horizontally to see the rest of the table.

Specification table
FeatureStandard model information
Analysis methodNear infrared transmission (NIR / NIT)
optical systemSBCS scanning grating monochromator
Spectral range790–1064 nm (product sheet)
Analysis timeApproximately 1 minutes
Hectolitre weightNo internal hectoliter module in standard model
Screen5,7 inch, 640 × 480 color touch
Dimensions (W×H×D)350 × 340 × 330 mm
Weight10 kg
Supply100–240 VAC / 12 V / 10 A
power consumption50 VA
operating temperature10–45 °C
Optical path length4–33 mm, automatic tuning
PrinterBuilt-in thermal printer
Links3 × USB 2.0, LAN, Wi-Fi

The technical chart is based on the official model sheet. The version and hardware scope to be delivered are specified in the offer. Analysis time belongs to the measurement of a sample; Sample acceptance, cleaning and verification steps are also included in the daily capacity calculation.

Calibration scope and reference verification

In order for the device to convert the spectrum into a result, calibration of the relevant product and component is required. The information “measures wheat” does not mean that the same package covers every grain or all parameters. Specify the sample type, target parameter, expected upper/lower values, and reference analysis method.

The nitrogen–protein factor used in the protein result and the dry matter/original sample basis should be comparable. Determine acceptance criteria by comparing instrument and reference results with representative samples at the installation; Review the inspection plan after new crop, season or maintenance. Explore the scope of calibration and verification service.

Accessories and scope of delivery

Scroll horizontally to see the rest of the table.

Separation of hardware and delivery package
PenHow to clarify?
Flour and ground sample cuvetteRequired for these applications; The suitable cuvette and its quantity are stated in the delivery list.
Power supply and connectionsSpecify appropriate external power supply and handling/installation conditions for different operating points.
Calibration packageProducts, parameters, measuring ranges and the package to be installed are listed.
Printer and consumablesInternal printer is a standard model feature; Delivery of paper and consumables is also stated.
InfraCloud and data transferInternet connection, access conditions and desired recording/transfer flow are evaluated together.
Installation, training and transportationApplication location, number of users, delivery and service scope are explained in separate items in the offer.

What information should be included in the quote?

Instead of pricing the model on its own, define the package that will work in your business. Include sample types, parameters, number of samples per day, study location and available reference method in your request for quotation. Device configuration, calibrations, cuvettes, power/connection accessories, training and delivery plan are prepared with these needs.

Current price, deadline, warranty and service conditions will be clarified in your written offer. Request a quote suitable for your sample for Infracont SGrain.

Frequently asked questions

Does a single device measure all parameters in every product?

Appropriate calibration is required for each product–parameter pair. The measuring range of the loaded package and sample is verified at the time of quotation and installation.

Is additional equipment required for flour analysis?

A separate, suitable flour pan is required for flour and associated milled samples. Calibration and cuvette are selected together.

Are the values ​​in the calibration list a warranty result?

The range and statistics given in the list indicate the definition of the relevant calibration. The suitability of the delivered device on your real samples is evaluated by reference comparison.

Is this device suitable for your business?

Let our expert team determine the right analysis system according to your needs.

FROM INFORMATION TO THE RIGHT CHOICE

Product selection and technical support

Review relevant models, selection guide and support coverage for your application.

WhatsApp
MAK ANALİZ

Get in touch

Tell us about your product, quotation or technical support enquiry.

Please write at least 10 characters.

Fields marked * are required. Your details are used to respond to your enquiry. Privacy policy (Turkish)